Contact Us Todayo: 405.288.0233f: 405.288.0238
Item ID
TM9Y060B12MP11
Description
96.0% AFUE LX Series Two Stage Standard ECM Multi-Position Residential Gas Furnace, 60/39 MBH Input, 58/37 MBH Output, 1200 CFM Nominal, Natural Gas
Manufacture
luxaire
Item Desc
Luxaire 96% 2 Stage STD ECM 60lbtu
AFUE
96%
Approximate Operating Weights Lbs
119
Blower - Amps
6.8
Blower - HP
1/2
Blower Size - Inch
11 x 8
Cabinet Dimensions - A
17-1/2"
Cabinet Dimensions - B
16-3/8"
Cabinet Dimensions - C
13-1/4"
Cabinet Size
B
Gas
Natural
High Fire Air Temp# Rise °F
35-65
Input High/Low - MBH
60/39
Low Fire Air Temp# Rise °F
35-65
Max Over-Current Protect
15
Max# Outlet Air Temp °F
190
Min# Wire Size (AWG) @ 75 ft# One Way
14
Nominal CFM (m3/min)
1200
Output High/Low - MBH
58/37
Total Unit Amps
9.5
Mfg Part Number
TM9Y060B12MP11
• Two stage heating operation includes two stage gas valve, two stage inducer operation and constant torque standard ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat. • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary. • Compact, easy to install, ideal height 33" tall cabinet. • Standard ECM constant torque drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance. • Easy access to controls to connect power/control wiring. • Built-in, high level self diagnostics with fault code display. • Low unit current draw requirement for easy replacement application. • Convertible to use propane (LP) gas. • Electronic Hot Surface Ignition saves fuel use with increased dependability and reliability. • 100% shut off main gas valve for extra safety. • 24V, 40 VA control transformer and integrated furnace control supplied for add-on cooling. • Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency. • Solid removable bottom panel allows easy conversion. • Airflow leakage less than 1% of nominal airflow for duct blaster conditions. • No knockouts to deal with, making installation easier. • Movable duct connector flanges for application flexibility. • Quiet inducer operation, burner, and blower operation. • Inducer rotates for easy conversion of venting options. • Fully supported blower assembly for easy access and removal of blower. • External air filters used for maximum flexibility in meeting customers IAQ needs. • Insulated blower compartment for thermal and acoustic performance. • 1/4 turn knobs provided for easy independent door removal. • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems. • Protection included from air intake, exhaust vent or condensate blockage. • Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air.