Contact Us Todayo: 405.288.0233f: 405.288.0238
Item ID
PCG4B481002X1
Description
4.0 Ton, Single Package Air Conditioner / Gas Heat, 14 Seer, R-410A, 1 Phase, 51" Length, 45-3/4" Width, 53" Height, 1600, 208 Voltage, 60 Hertz
Manufacture
luxaire
Item Desc
Luxaire 4T 14Seer gas pack 100k btu
AFUE %
81.0
AHRI net capacity (MBH)
45.5
Cabinet Size
Large 45 x 51
Compressor LRA
117.0
Compressor MCC
34.0
Compressor RLA
21.8
Compressors Type
Scroll
Condenser Coil Circuitry Type
Interlaced
Condenser Coil Face Area (Sq# Ft#)
23.8
Condenser Coil Fins per inch
22
Condenser Coil Rows
2
Condenser Coil Tube diameter
3/8
Condenser Fan Diameter (Inch)
26
Condenser Fan Drive Type
Direct
Condenser Fan Motor HP Each
1/3
Condenser Fan No# Speeds
1
Condenser Fan Nominal Total CFM
3200
Condenser Fan RPM
850
Condenser Fan Type
Prop
Direct Drive Evaporator Fan Frame size
48
Direct Drive Evaporator Fan Motor HP each
3/4
Direct Drive Evaporator Fan RPM
1200 Max
Direct Drive Evaporator Fan Size (Inch)
11 x 10
Direct Drive Evaporator Fan Type
Centrifugal
EER
11.0
Evaporator Coil Circuitry Type
Interlaced
Evaporator Coil Face area (Sq# Ft#)
6.3
Evaporator Coil Fins per inch
16
Evaporator Coil Refrigerant Control
TXV
Evaporator Coil Rows
3
Evaporator Coil Tube Diameter
3/8
Mfg# Part Number
PCG4B481002X1
• Operating Efficiency - All PCG4 model gas units provide a minimum AFUE of 81.0% in heating and 14.0 SEER, 11.0 EER rating for cooling operation. All models meet California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts. • On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper capacity unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side shot to down shot allows the installer to have greater flexibility with less inventory. • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers during assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size side supply and return duct connections allow easy connection of ducts to match low crawl spaces without transition pieces. • Utility Connections Made Easy - Gas and electric utility access provided through the bottom or the side of the unit. • Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed. • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/side return duct openings. No panel cutting is required and no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory. • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality). • Condensate Drain - The 3/4 inch NPT female connection is rigidly mounted to assure proper fit and leak tight seal. • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paintto-steel bond, which resists corrosion and rust creep. Powder paint finish insure less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested). • Full Perimeter Base Rails - The easily removable base rails provide a solid foundation for the entire unit and protects the unit during shipment. The rails provide fork lift access from all sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. On applications where the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applications where height is limited, the base rails may be removed by removing 2 screws in each corner. • More Attractive Appearance - A single-piece top cover containing a top-discharge outdoor fan arrangement requires less square footage on installation and provides a wider variety of installations. The one-piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. • Top Discharge - The top-discharge outdoor fan does not disrupt neighboring areas or dry out vegetation surrounding the unit. The warm air from the top mounted fan is blown up and away from the structure and any landscaping. This allows compact location on multi-unit applications. • Outdoor Coil Grille - All models utilize a stamped slotted design which provides superior impact protection against small objects during transit and after installation. • Low Operating Sound Level - The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates noise. Isolator mounted compressor and the rippled fins of the outdoor coil muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound attenuation with its structural design. This design strategically places embossments in the pan for optimum strength and rigidity. • Fan System - All models operate over a wide range of design conditions with a standard ECM indoor fan motor. These units easily match all types of applications and provide greater on-site flexibility to match comfort requirements. The cooling speed is factory-set and can be field-adjusted to a second speed. The heating speed is factory set to maintain mid point rise at the units heating input, but can be field adjusted. This allows maximum comfort conditions. • Simple Control Circuit - A low voltage gas heat printed circuit board contains a status/diagnostic indicator light. Field thermostat wiring connects to color coded leads using twist on wire connections. Cooling controls use contactor and relays for simple application and troubleshooting. Mate-nlock plug connectors are used. The electrical control box is not located in the compressor compartment. The controls are mounted to allow the separate access panel to be removed for trouble shooting and maintenance without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. • Protected Compressor - The compressor is internally protected against high pressure and temperature. This is accomplished by the simultaneous operation of high pressure relief valve and a temperature sensor which protect the compressor if undesirable operating conditions occur. • Pressure Switches - A high pressure switch is standard in all units. When abnormal conditions are sensed through the pressure switch, the unit will lock out preventing any further operation until reset or problem is corrected. • Exclusive Coil Design - Grooved copper tubes and enhanced aluminum fin construction improves heat transfer for maximum efficiency and durability for long-lasting durability and efficient operation. Indoor coils use tin-coated copper tubing with aluminum fins for effective heat transfer. • Heat Exchangers - Gas heat exchangers use corrosionresistant, stainless-steel tubular construction to provide longlife, trouble-free operation. Gas heat exchangers are offered with lifetime warranties as standard with registration. • Post Purge Induced Draft Combustion - Exhausts combustion products from the heat exchanger upon completion of the heating cycle to prolong the heat exchanger life. • Spark To Burner Ignition - No pilot assembly required, which provides more consistent ignition in gas heating mode. This ignition is highly reliable, durable and eliminates nuisance lockouts. • Multi Port In-shot Burners - No field adjustment is required to mix the air and gas for natural gas or propane use. These burners are constructed of high-grade corrosion-resistant, aluminized steel. • Low Maintenance - Long life, permanently lubricated outdoor and evaporator fan motor bearings need no annual maintenance, adding greater reliability to the unit. Slide-out blower assembly can be easily removed for cleaning. • Easy Service Access - Individual access panels covering the electrical and gas controls makes servicing easy. Removing this panel will allow easy removal of the blower assembly for maintenance and ease of troubleshooting. • Replacement Parts - The installer requires no special training to replace any of the components of these units and the number of new components have been reduced to minimize the inventory of unique parts.