Item ID
GAW14L48C22S
Description
4.0 Ton, LX Series Split System Air Conditioners Shipped With Nitrogen Charge Only, 14 SEER / 1-Stage, R-407C, 1 Phase
Manufacture
luxaire
Item Desc
4T 14 SEER GUARDIAN R407C COND
Brand
OTC Factory Branded
Cabinet And Connection Type
New Chassis Louvered / Sweat Connect
Charge Per Foot, Oz#
0.65
Coil Face Area Sq# Ft#
25.65
Coil Fins / Inch
23
Coil Rows Deep
1
Compressor Locked Rotor
104.0
Compressor Rated Load
19.8
Compressors Type
Scroll
Crankcase Heater
No
Factory External Check Valve
No
Factory External Discharge Muffler
No
Factory Option
Standard (No Options)
Fan Diameter Inches
26
Fan Motor Nominal CFM
3800
Fan Motor Nominal RPM
850
Fan Motor Rated HP
1/4
Fan Motor Rated Load Amps
1.3
Generation Level
First Generation
Height
36-1/4"
HS Kit Required with TXV
No
Length
34-1/4"
Liquid Line Set OD (Field Installed)
3/8
Max# Overcurrent Device Amps
45
Min# Overcurrent Device Amps
30
Minimum Circuit Ampacity
26.1
Nominal Series Efficiency and Staging
14 SEER / 1-Stage
Nominal Unit Capacity (MBH)
4.0 Ton
Normal Voltage Range
187 to 252
Operating WT# (lbs#)
1.70
Mfg# Part Number
GAW14L48C21S
• Easier Installation - Independent panels provide quick access for unit setup. Installation time is reduced by easy power and control wiring access. The factory installed filterdrier means less time spent brazing and charging the system. The small base dimension and reduced unit clearances make for easier retrofits. • Durable Finish - The coated steel wire fan guard, coated external fasteners, and pre-treated G90-equivalent galvanized steel chassis components resist corrosion and rust creep. Powdercoat paint further protects external panels. • Louvered Coil Protection - Two stamped steel louvered panels protect the coil from mechanical damage. • Quality Coils - The high efficiency microchannel aluminum coil is manufactured using an improved material system providing reliable performance and small unit size. • Protected Compressor - Compressors are protected internally by a high pressure relief valve and a temperature sensor. The liquid line filter-drier is factory installed to protect the compressor against moisture and debris. • R-407C Charge - Shipped with R-407C charge. R-407C refrigerant must be field sourced and charged. • Top Discharge - Warm air is blown up, away from the structure and any landscaping and allows compact location on multi-unit applications. • Agency Listed - Safety certified by CSA to UL 1995 / CSA 22.2. Performance certified to ANSI/AHRI Standard 210/240 in accordance with the Unitary Small Equipment certification program.