Contact Us Todayo: 405.288.0233f: 405.288.0238
Item ID
CF42BXA1
Description
3.5 Ton, Upflow/Downflow Full Cased Luxaire Evaporator Coil, 1400 Rated CFM, 17.5" Cabinet Width, 25" Height, 17-1/2" Width, 16-1/2" Opening Width
Manufacture
Luxaire
Item Desc
Luxaire 3.5T Vertical Coil
Application
Cooling /Heat Pump
Cabinet Width
17.5"
Coil Size
(3) 22 x 17.1
Coil Type
MaxAlloy Aluminum Tube
Face Area (Sq# Ft#)
7.84
Fin Type
Sine Wave
Fins Per In#
14
Generation
1st Gen
Height
25"
Installed Weight (lbs)
56
Metering Device
No Valve (Flex Coil)
Model
CF42B
Nominal Unit Capacity
3.5 Ton
Opening Width
16-1/2"
Position Motor Type
Full Cased, Upflow/Downflow
Product Type
Indoor Coil
Rated CFM
1400
Refrig# Conn#Types
Sweat
Refrigerant Connections Liquid
3/8
Refrigerant Connections Vapor
7/8
Rows Deep
2
Shipping Weight (lbs)
57
Tube Dia#
3/8
Tube Geometry
1 x 0.866
Width
17-1/2"
Mfg# Part Number
CF42BXA1
• CF series full cased coils are suitable for upflow or downflow applications. • Rigid Case Construction - an interior endoskeleton provides structural support eliminating screw heads protruding from the side of the cabinet that could damage property when being installed. • Cabinet – Constructed of heavy gauge galvanized steel with a primer and finish coat providing a high quality corrosion resistant finish. • MaxAlloy Coil - Long life aluminum coils built to deliver lasting performance, efficiency and reliability. • Foil faced insulation -The cabinet is insulated with a single piece of cleanable foil faced insulation retained by the endoskeleton. The cabinet design is such that all edges of the insulation are contained. • Electronic Expansion Valve (EEV) - Factory installed on select CM models and sized to match with specific high-efficiency variable capacity outdoor units. • Compact Cabinet - With the coil and access doors removed the cabinet has a 20.5” casing depth in all models, which provide ease of attic access and space constrained applications. • Thermoset Drain Pan - Corrosion and UV resistant with a positive slope for proper drainage. Low water retention design maximizes indoor air quality and consumer comfort. • Low Leakage Cabinet Design - Fully gasketed doors minimizes air leakage to no more than 2% when measured at 1.0” esp. minimizing conditioned air leakage and infiltration. • Duct Flange - Three sided duct flange is supplied to be field installed when required. • Thermostatic Expansion Valves - Select factory mounted as well as field mounted models available utilizing chatleff fittings, no brazing required.